"Air Filter Materials and Building Related Symptoms in the BASE Study." Healthy Buildings Conference 2006 2006: 455-460.
. "Air Filter Materials, Outdoor Ozone and Building-Related Symptoms in the BASE Study." Indoor Air 18 (2008) 144-155.
. Are ventilation filters degrading indoor air quality in California classrooms?. Berkeley, CA: Lawrence Berkeley National Laboratory, 2009.
. "Association of Classroom Ventilation with Reduced Illness Absence: A Prospective Study in California Elementary Schools." Indoor Air 23.6 (2013) 515-528. LBNL-6259E.
. "Associations between classroom CO2 concentrations and student attendance in Washington and Idaho." Indoor Air 2004 14 (2004) 333-341.
. . "Associations between Indoor CO2 Concentrations and Sick Building Syndrome Symptoms in US Office Buildings: An Analysis of the 1994-1996 BASE Study Data." Indoor Air 10.4 (2000) 246-257. LBNL-44385.
. . "California Demonstration Energy Efficiency-Indoor Environmental Quality Project: Predicted Relocatable Classroom Indoor Air Quality due to Low-Emitting Interior Materials and Enhanced Ventilation." 11th Annual Meeting of the International Society of Exposure Analysis, November 4-8, 2001. Charleston, SC: International Society for Exposure Analysis, Boston, MA, 2001.
. "Characterization Of Reaction Products And Ultrafine Particles From Ozone-initiated Chemistry On Filters From Ventilation Systems In Commercial Buildings." 12th International Conference on Indoor Air Quality and Climate, June 5-10, 2011. Austin, TX: Proceedings of Indoor Air 2011, a885 3, 2011.
. "Characterizing ETS Emissions from Cigars: Chamber Measurements of Nicotine, Particle Mass, and Particle Size." Proceedings of the Indoor Air '99 Conference, Edinburgh, Scotland 1999: 903-908.
. Classroom HVAC: Improving ventilation and saving energy field study plan. Lawrence Berkeley National Laboratory, 2004.
. "Comparison of predicted and derived measures of volatile organic compounds inside four relocatable classrooms due to identified interior finish sources." Indoor Air (Supplement 8) 14 (2004) 135-144. LBNL-52520.
. "Designing Building Systems to Save Energy and Improve Indoor Environments: A Practical Demonstration." 2004 ACEEE Summer Study on Energy Efficiency in Buildings 2004: 13-27.
. "Determining Size-Specific Emission Factors for Environmental Tobacco Smoke Particles." Aerosol Science & Technology 37.10 (2003) 780-790.
. . Development of a Low-Cost Particulate Matter Monitor. Berkeley: Lawrence Berkeley National Laboratory, 2008.
. "Energy and Indoor Environmental Quality in Relocatable Classrooms." Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate. II. Monterey, CA, 2002. 62-69. LBNL-49581.
. Energy savings estimates and cost benefit calculations for high performance relocatable classrooms. Lawrence Berkeley National Laboratory, 2004.
. "Estimated Ventilation Rates and Work-Related Symptoms in U.S. Office Buildings - The Base Study." . 10th International Conference on Indoor Air Quality and Climate 2005: 3758-3762. LBNL-57102.
. Experimental Evaluation of Installed Cooking Exhaust Fan Performance. Berkeley: Lawrence Berkeley National Laboratory, 2010. LBNL-4183E.
. "An Exploratory Analysis of the Relationship between Mortality and the Chemical Composition of Airborne Particulate Matter." Inhalation Toxicology 12.Supplement 2 (2000) 121-135. LBNL-43583.
. Field Derived Emission Factors For Formaldehyde and other Volatile Organic Compounds in FEMA Temporary Housing Units. Berkeley: Lawrence Berkeley National Laboratory, 2010. LBNL-4083E.
. Final methodology for a field study of indoor environmental quality and energy efficiency in new relocatable classrooms in Northern California. 2002. LBNL-51101.
. Final Report: Balancing energy conservation and occupant needs in ventilation rate standards for “Big Box” stores in California: predicted indoor air quality and energy consumption using a matrix of ventilation scenarios. Berkeley: Lawrence Berkeley National Laboratory, 2011. LBNL-5551E.
.