Publications
Export 37 results:
Author [ Title
Filters: Author is Randy L. Maddalena [Clear All Filters]
"Addressing locally grown foods in cumulative exposure assessments." Journal of Exposure Analysis and Environmental Epidemiology 14 (2002) 60-73.
. "Applications of contaminant fate and bioaccumulation models in assessing ecological risks of chemicals: A case study for gasoline hydrocarbons." Environmental Science & Technology 38.23 (2004) 6225 -6233.
. Background Air Component of Measured Vegetation/Soil Bioconcentration Ratios. Lawrence Berkeley National Laboratory, 2006.
. "BETR North America: A regionally segmented multimedia contaminant fate model for North America." Environmental Science & Pollution Research 8 (2001) 156-163.
. "Dependence of Intake Fraction on Release Location in a Multimedia Framework - A Case Study of Four Contaminants in North America." Journal of Industrial Ecology 8.3 (2004) 89-102.
. . "Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making." Indoor Air 25.4 (2015) 362-370.
. "Exposure chamber measurements of mass transfer and partitioning at the plant/air interface." Environmental Science & Technology 36.16 (2002) 3577-3585.
. Field Derived Emission Factors For Formaldehyde and other Volatile Organic Compounds in FEMA Temporary Housing Units. Berkeley: Lawrence Berkeley National Laboratory, 2010. LBNL-4083E.
. Field Measurement of polycyclic aromatic hydrocarbons in wheat grain grown in Sacramento and San Joaquin Valleys, California. Lawrence Berkeley National Laboratory, 2006. LBNL-60312.
. "Formaldehyde and Other Volatile Organic Chemical Emissions in Four FEMA Temporary Housing Units." Environmental Science and Technology 43 (2009) 5626-5632.
. A Formaldehyde Exposure Assessment Tool for Occupants of FEMA Temporary Housing Units. Berkeley: Lawrence Berkeley National Laboratory, 2010.
. Healthy Efficient New Gas Homes (HENGH) Pilot Test Results. 2016. LBNL-1005818.
. Identifying Sources of Volatile Organic Compounds and Aldehydes in a High Performance Building. Berkeley: Lawrence Berkeley National Laboratory, 2010. LBNL-3979E.
. Impact of Independently Controlling Ventilation Rate per Person and Ventilation Rate per Floor Area on Perceived Air Quality, Sick Building Symptoms and Decision Making. 2013. LBNL-6549e (REV).
. "The impact of ventilation rate on the emission rates of volatile organic compounds in residences." Healthy Buildings 2012 - 10th International Conference. Brisbane, Australia, 2012.
. Indoor Air Quality Assessment of the San Francisco Federal Building. Berkeley: Lawrence Berkeley National Laboratory, 2009.
. "Indoor pollutants emitted by electronic office equipment." Indoor Air 2008 (2008).
. "Indoor pollutants emitted by office equipment: A review of reported data and information needs." Atmospheric Environment 42 (2008) 1371-1388. LBNL-62082.
. "Influential input classification in probabilistic multimedia models." Stochastic Environmental Research and Risk Assessment 15.1 (2001) 1-17.
. . "Maximizing Information from Residential Measurements of Volatile Organic Compounds." Healthy Buildings 2012 - 10th International Conference. Brisbane, Australia, 2013. LBNL-6120E.
. Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling. Berkeley: Lawrence Berkeley National Laboratory, 2013. LBNL-6257E.
. "Plant Uptake of Organic Pollutants from Soil: Bioconcentration Estimates Based on Models and Experiments-Review." Environmental Toxicology and Chemistry 26 (2007) 2494-504.
. "Plant Uptake of Organic Pollutants from Soil: Model Performance Evaluation." Environmental Toxicology and Chemistry 26 (2007) 2494–2504.
.